OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray

Short Description:


Product Detail

Payment & Shipping Terms:

Product Tags

Related Video

Feedback (2)

Control the quality by the details, show the power by quality. Our enterprise has strived to establish a remarkably efficient and stable team team and explored an effective excellent control system for Rotating Anode Xray Tube, Modern X Ray Tube, Radiographic Filters, Honesty is our principle, skilled procedure is our perform, service is our target, and customers' satisfaction is our long term!
OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray Detail:

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 85kV
Nominal Focal Spot 1.5(IEC60336/2005)
Filament Characteristics Ifmax=2.6A, Uf=3.0±0.5V
Nominal Input Power(at 1.0s) 1.8kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 10kJ
Target Angle 23°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx.120g

RT12-1.4-85

Cautions

Read the cautions before using the tube

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent life time
Certification:  SFDA


Product detail pictures:

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of OEM High Quality Modern Coolidge Tube Factories - Dental X-ray Tube Xd2 – Sailray , The product will supply to all over the world, such as: Moscow, Mali, Roman, To have much more enterprise. ompanions, we've got updated the item list and seek for optimistic co-operation. Our web-site shows the latest and complete information and facts about our merchandise list and company. For further acknowledge, our consultant service group in Bulgaria will reply to all of the inquiries and complications immediately. They're about to make their finest effort to meet buyers need. Also we support the delivery of absolutely free samples. Business visits to our business in Bulgaria and factory are generally welcome for a win-win negotiation. Hope to expertise a happy company co-operation perform with you.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • The company keeps to the operation concept scientific management, high quality and efficiency primacy, customer supreme, we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Miguel from Swansea - 2018.11.22 12:28
    We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Ella from Seattle - 2018.04.25 16:46
    Write your message here and send it to us