Medical X-ray Collimator Manual X-ray beam limitter SR202

Medical X-ray Collimator Manual X-ray beam limitter SR202

Medical X-ray Collimator Manual X-ray beam limitter SR202

Short Description:

Features
Compatible with X-ray diagnostic equipment using 150kV tube voltage, including DR digital systems and conventional systems
 The X-ray irradiation field is rectangular
Conform to relevant national and industry standards
Small size
High reliability and high cost performance
Uses a single layer, two sets of lead leaves and a specialized internal protection design to block X-rays.
The adjustment of the irradiation field is manual, continuously adjustable
The visible light field adopts LED bulbs
A built-in delay circuit automatically turns off the lamp 30 seconds after activation, and a manual option to turn off the light during operation is also available. These features are designed to extend the life of the bulb and reduce energy consumption.


Product Detail

Payment & Shipping Terms:

Product Tags

Main technical parameters and indicators

X-ray leakage: <1mGy/h (150kV, 4mA)
This distance can be adjusted according to the specific X-ray tube used. The standard distance is 60mm from the focus of the X-ray tube to the mounting surface of the beam limiter.
Maximum irradiation field: 43cmX43cm (SID=1m)
Minimum irradiation field: <5cmX5cm (SID=1m)
 Visible light field brightness: >140lux (SID=1m)
Light field consistency: <2%@SID
Inherent filtration: 1mmAl/75kV
Power input: 24VAC/50W or 24VDC/50W
 Dimensions: 185mm×198mm×145mm (length×width×height)
Weight: 6.2kg

Optional:
External additional filter
Special electrical interface
Special tube ball interface
One word line laser locator

Technical parameters

Max Voltage

150KV

Maximum X-ray field  coverage  range

440mm×440mm (SID=100cm)

The average brightness of the light field

>160 lux

Edge contrast ratio

>4:1

Power supply requirement of projection lamp

24V/150W

Bright  X-ray  field  duration  for  Once

30S

Distance from Focal Spot of X-ray tube to the mount plane of collimator  SID  (mm)(optional)

60

Filtration(Inherent) 75kV

1mmAl

Filtration(Additional)

The outer optional

Control  method

Manual

Drive motor

--

Motor Control

--

Position detection

--

Input power

AC24V

(SID)Measuring tape

Standard Configuration

Center laser instructions

optional

Dimension(mm)(W×L×H)

185×198×145

Weight(Kg)

6.8

Applications

This x-ray collimator is suitable for tube voltage 150kV, DR digital and common X-ray diagnostic equipment.


  • Previous:
  • Next:

  • Minimum Order Quantity: 1pc

    Price: Negotiation

    Packaging Details: 100pcs per carton or customized according to the quantity

    Delivery Time: 1~2 weeks according to the quantity

    Payment Terms: 100% T/T in advance or WESTERN UNION

    Supply Ability: 1000pcs/ month

  • Write your message here and send it to us