
OEM High Quality Varex Tube Supplier - Medical X-ray Tube CEI OX105-6 – Sailray
KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
KL1-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a ...


China wholesale Wedge Filter Radiography Factories - X-ray shielding Lead glass 36 ZF2 – Sailray
Key benefits
·Shields against X-Ray from equipment operating in the 80 to 300kV range
·High Barium and lead content providing optimum protection with excellent visual clarity
·Supplied as polished plates, cut accoring to customer requirements up to 2400X 1200 mm, allowing architects to design viewing windows with a wider field of vision.
·Also available in sizes cut specifically to customer requirements (with cut edges ground or polished and finished with safety chamfers.
·Extensive stocks he...

China wholesale Portable Dental Xray Unit Factory - Mobile X-ray Tube Cei OX110-5 – Sailray
KL25-0.6/1.5-110 stationary anode x-ray tube is especially designed for C-arm equipment and available for nominal tube voltage with high frequency or DC generator.
The integrated high quality tube with glass design has two super imposed focal spot and a reinforced anode. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tu...

OEM High Quality Coolidge Tube Factory - Dental X-ray Tube Xd2 – Sailray
This tube, RT12-1.5-85 is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of i...

China wholesale Rotating Anode X Ray Suppliers - Rotating Anode X-ray Tubes MWTX73-0.6_1.2-150H – Sailray
Maximum Operating Voltage
150KV
Focal Spot Size
0.6/1.2
Diameter
73mm
Target Materia
RTM
Anode Angle
12°
Rotation Speed
2800/8400RPM
Heat Storage
300kHU
Maximum Continuous Dissipation
750W
Large Focus
5.4A
Small Focus
5.4A
Inherent Filtration
1mmAl/75KV(IEC60522/1999)
Maximum Power(0.1S)
(50/60Hz) 20KW/50KW
(150/180Hz) 30KW/74KW
Anode drive:150Hz/180Hz
X-ray tube will emit X-ray when it is energized with high voltage, Special knowledge s...


OEM High Quality X Ray Tube Head Dental Manufacturer - Medical X-ray Tube CEI OX105-6 – Sailray
KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
KL1-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a ...

OEM High Quality Rotating Anode Xray Tube Manufacturer - Dental X-ray Tube CEI Ox_70-m – Sailray
KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
KL1-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a ...

China wholesale Ct Scan Filters Suppliers - X-ray shielding Lead glass 36 ZF2 – Sailray
Key benefits
·Shields against X-Ray from equipment operating in the 80 to 300kV range
·High Barium and lead content providing optimum protection with excellent visual clarity
·Supplied as polished plates, cut accoring to customer requirements up to 2400X 1200 mm, allowing architects to design viewing windows with a wider field of vision.
·Also available in sizes cut specifically to customer requirements (with cut edges ground or polished and finished with safety chamfers.
·Extensive stocks he...

OEM High Quality X-Ray Tube Assembly Manufacturer - Housing for Rotating anode tubes – Sailray
As an important part of the X-ray tube assembly, the X-ray tube housing provides a lead cylinder for shielding rays for the rotating anode X-ray tube, the stator which drives the rotating anode tube, encloses the rotating anode X-ray tube, and is equipped with high-voltage cables interface, insulating oil, expanders that prevent excessive pressure due to temperature changes and oil volume changes, sealed metal casings, etc. We provide x-ray tube housing which is suitable for tube assemblies m...

OEM High Quality Dental X Ray Machine Tube Head Manufacturers - Medical X-ray Tube CEI OX105-6 – Sailray
KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
KL1-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a ...