China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray

Short Description:


Product Detail

Payment & Shipping Terms:

Product Tags

Related Video

Feedback (2)

To fulfill the customers' over-expected fulfillment , we have now our solid staff to deliver our greatest general assistance which includes internet marketing, product sales, creating, manufacturing, excellent controlling, packing, warehousing and logistics for Glass X Ray Tube, Lead Glass Radiation Shielding, Modern X Ray Tube, We warmly welcome merchants from your home and overseas to contact us and set up business enterprise partnership with us, and we'll do our greatest to serve you.
China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray Detail:

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

This tube, RT12-1.5-85  is designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 85kV
Nominal Focal Spot 1.5(IEC60336/2005)
Filament Characteristics Ifmax=2.6A, Uf=3.0±0.5V
Nominal Input Power(at 1.0s) 1.8kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 10kJ
Target Angle 23°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx.120g

RT12-1.4-85

Cautions

Read the cautions before using the tube

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent life time
Certification:  SFDA


Product detail pictures:

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures

China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray detail pictures


Related Product Guide:

Assume full accountability to satisfy all demands of our consumers; reach ongoing advancements by endorsing the expansion of our purchasers; come to be the final permanent cooperative partner of clients and maximize the interests of clientele for China wholesale Rotanode Factories - Dental X-ray Tube Xd2 – Sailray , The product will supply to all over the world, such as: Birmingham, Slovenia, Hongkong, We've got a dedicated and aggressive sales team, and many branches, catering to our customers. We are looking for long-term business partnerships, and ensure our suppliers that they will absolutely benefit in both short and long run.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • In China, we have purchased many times, this time is the most successful and most satisfactory, a sincere and realiable Chinese manufacturer!
    5 Stars By April from Swedish - 2018.09.12 17:18
    The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Ada from Swiss - 2017.04.28 15:45
    Write your message here and send it to us