China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray

China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray

China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray

Short Description:


Product Detail

Payment & Shipping Terms:

Product Tags

Related Video

Feedback (2)

We keep improving and perfecting our products and service. At the same time, we work actively to do research and development for Tube Head Dental X Ray, Lead Goggles Radiation Protection, X Ray Lead Glass, Customer satisfaction is our main goal. We welcome you to establish business relation with us. For further information, please don't hesitate to contact with us.
China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray Detail:

KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
KL1-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

KL1-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.

Nominal Tube Voltage 70kV
Nominal Inverse Voltage 85kV
Nominal Focal Spot 0.8 (IEC60336/1993)
Max. Anode Heat content 7000J
Max. Current Continuous Service 2mA x 70kV
Max. Anode Cooling Rate 140W
Target Angle 19°
Filament Characteristics 1.8 – 2.2A, 2.4 – 3.3V
Permanent Filtration Min. 0.6mm Al / 50 kV(IEC60522/1999)
Target Material Tungsten
Nominal Anode Input Power 840W

details

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent lifetime

Prior to usage, season the tube in accordance with the seasoning schedule given below until the required tube voltage is attained. Example given – needs to revise by the manufacturer and specified in the data sheet of the part:

Initial incoming seasoning and seasoning schedule for idle period (more than6months)Circuit:

When the tube current is unstable in seasoning, immediately switch off the tube voltage and after an interval of 5 minutes or more, increase the tube voltage gradually from the low voltage while making sure that the tube current is stable. The withstand voltage performance of the tube unit will be lowered as the exposure time and the number of operation increase. Stain-like impact traces might appear on the x-ray tube target surface by slight discharge in the course of the seasoning. These phenomena are one process to recover the withstanding voltage performance at that time. Therefore, if it is in stable operation at the maximum tube voltage of seasoning subsequent to them, the tube unit can be used without any interference to its electrical performance which in use.

Cautions

Read the cautions before using the tube

 

X-ray tube will emit X –ray when it is energized with high voltage, Special knowledge should be required and cautions need to be taken when handling it。

 

1. Only a qualified specialist with X-Ray tube knowledge should assemble, maintain and remove the tube。

2. Sufficient care should be taken to avoid strong impact and vibration to the tube because  it is made of fragile glass。

3. Radiation protection of the tube unit must be sufficiently taken。

4. The minimum sorce-skin distance (SSD) and the minimum filtration should match the regulation and meet the standard。

5. The system should have proper overload protection circuit, the tube may be damaged due to only one overload operation。

6. When any abnormalities are found during operation, immediately switch off the power supply and contact the service engineer。

7. if the tube is with a lead shield, to dispose of lead shield must meet government regulations。


Product detail pictures:

China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray detail pictures

China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray detail pictures

China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray detail pictures


Related Product Guide:

We keep on with our enterprise spirit of Quality, Efficiency, Innovation and Integrity. We intention to create extra worth for our buyers with our prosperous resources, superior machinery, experienced workers and superb services for China wholesale Iae Tube Suppliers - Dental X-ray Tube CEI Ox_70-m – Sailray , The product will supply to all over the world, such as: Saudi Arabia, Dubai, Pakistan, We seriously promise that we provide all the customers with the best quality products, the most competitive prices and the most prompt delivery. We hope to win a resplendent future for customers and ourselves.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Marcie Green from Plymouth - 2018.05.15 10:52
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Annabelle from Bangkok - 2018.06.12 16:22
    Write your message here and send it to us