we could supply good quality goods, aggressive cost and very best purchaser assistance. Our destination is You come here with difficulty and we supply you with a smile to take away for Micro X Ray Tube, X Ray Tube In Ct, X Ray Protection Goggles, We warmly welcome domestic and abroad buyers deliver inquiry to us ,we now have 24hours doing work team! Anytime anywhere we are still here to be your partner.
China wholesale Compensating Filters In Radiology Factory - Mobile X-ray Tube CEI 110-15 – Sailray Detail:

KL10-0.6/1.8-110 Stationary anode X-Ray tube is especially designed for Mobile Units for radiography, for Portable Radiographic Units, and available for a nominal tube voltage with high frequency or DC generator.
The integrated high quality tube with glass design has one super imposed focal spot and a reinforced anode.
The high anode heat storage capacity ensures a wide range of applications for mobile, portable applications. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.

KL10-0.6/1.8-110 Stationary anode X-Ray tube is especially designed for Mobile Units for radiography, for Portable Radiographic Units, and available for a nominal tube voltage with high frequency or DC generator.

Nominal Tube Voltage 110kV
Nominal Focal Spot small:0.6   large:1.8(IEC60336/2005)
Filament Characteristics small:Ifmax=4.5A,Uf=5±0.5  large:Ifmax=4.5A,Uf=6.3±0.8V
Nominal Input Power(at 1.0s) small:spot0.6kW  large:spot5.2kW
Maximum Continuous Rating 225W
Anode Heat Storage Capacity 30kJ
Target Angle 15°
Target Material Tungsten
Inherent Filtration Min 0.6mmAl equivalent at 75kV
Weight approx600g

AKL10-0.6-1.8-110

Maintaining seasoning schedule

Prior to usage, season the tube in accordance with the seasoning schedule given below until the required tube voltage is attained. Example given – needs to revise by the manufacturer and specified in the data sheet of the part: Initial incoming seasoning and seasoning schedule for idle period (more than 6 months) Circuit: DC (Center grounded)

KL10 老练图

When the tube current is unstable in seasoning, immediately switch off the tube voltage and after an interval of 5 minutes or more, increase the tube voltage gradually from the low voltage while making sure that the tube current is stable. The withstand voltage performance of the tube unit will be lowered as the exposure time and the number of operation increase. Stain-like impact traces might appear on the x-ray tube target surface by slight discharge in the course of the seasoning. These phenomena are one process to recover the withstanding voltage performance at that time. Therefore, if it is in stable operation at the maximum tube voltage of seasoning subsequent to them, the tube unit can be used without any interference to its electrical performance which in use.

Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent lifetime


Product detail pictures:

China wholesale Compensating Filters In Radiology Factory - Mobile X-ray Tube CEI 110-15 – Sailray detail pictures

China wholesale Compensating Filters In Radiology Factory - Mobile X-ray Tube CEI 110-15 – Sailray detail pictures

China wholesale Compensating Filters In Radiology Factory - Mobile X-ray Tube CEI 110-15 – Sailray detail pictures


Related Product Guide:

We're going to commit ourselves to giving our esteemed customers along with the most enthusiastically considerate providers for China wholesale Compensating Filters In Radiology Factory - Mobile X-ray Tube CEI 110-15 – Sailray , The product will supply to all over the world, such as: Juventus, Berlin, Hyderabad, If you need any of our products, or have other items to be produced, please send us your inquiries, samples or detailed drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.

Minimum Order Quantity: 1pc

Price: Negotiation

Packaging Details: 100pcs per carton or customized according to the quantity

Delivery Time: 1~2 weeks according to the quantity

Payment Terms: 100% T/T in advance or WESTERN UNION

Supply Ability: 1000pcs/ month

  • High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Ophelia from Barcelona - 2018.09.29 13:24
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Clementine from Serbia - 2017.12.31 14:53
    Write your message here and send it to us